Atlas & Yukon Second Stage
Final Testing Procedures
s e c t i o n
6
s e c t i o n
Final Testing Procedures
Fig. 20 - Inline Adjustment Tool w/ IP Gauge
CAUTION: If the regulator has been upgraded for use with
EAN/ Nitrox, it is important to pressurize and flow test the
regulator using only hydrocarbon-free gas. The regulator
will otherwise become contaminated with hydrocarbons if
normal compressed air is used. Industrial grade compressed
Nitrogen is strongly recommended as a less expensive al-
ternative to EAN/ Nitrox for the purposes of flow testing.
1. Connect the IP Test Gauge (PN 20-510-100) onto the inlet
fitting of the Inline Adjusting Tool (PN 20-500-200), and
mate the opposite fitting of the tool onto the inlet fitting of
the second stage. Pull back the knurled knob to retract the
slotted drive, and tighten the tool clockwise onto the inlet
fitting only until finger snug.
NOTE: Check to ensure that the knurled knob of the Inline
Adjustment Tool is set to the inner dimple, nearest to the
slotted drive, for the S.K.O. second stage. The extended
inlet coupling of the SideKick second stage will requre the
knurled knob to be set to the outer dimple, in order to pro-
vide the deeper reach that is needed for the slotted drive to
make contact with the orifice.
2. Install the O-ring(40) onto the post inside the female fitting
of the LP hose(39). Mate the female fitting of the LP hose
onto the male fitting of the IP Test Gauge, and tighten the
swivel nut clockwise until finger snug (see Fig. 20).
3. Install the O-ring(38) onto the male fitting of the LP hose,
and install the hose into an intermediate pressure port of a
first stage regulator that has been verified to be properly
serviced, with a stable intermediate pressure of 140 (±5)
psi . Apply a torque wrench with a b" crow-foot to
tighten the fitting to 38 (±2) inch-lbs.
CAUTION: If the second stage has been cleaned and ser-
viced for use with EAN/ Nitrox, it is important to connect it
with a first stage that has also been cleaned and serviced
accordingly, and to use only hydrocarbon-free gas while
performing this procedure. Use of standard compressed
air will otherwise contaminate the system.